Instructions for Upgrading of Meta Imaging Series 4.6 or 5.0 to 6.1In order to ensure that the installation onto your imaging system goes as smoothly as possible, we ask that you take the following steps prior to installing Meta Imaging Series 6.1 Software. You must turn on all of the peripherals connected to your imaging workstation prior to updating the software to version 6.1. This includes any cameras, filter-wheels, automated microscopes (that are controlled via Meta Imaging Series sotfware), Z-motors, stages, etc.Before Installation1. Operating SystemThe preferred operating system for Meta Imaging Series 6.1 is Microsoft Windows 2000 Professional SP3 or Windows XP Professional SP1 or greater. The software will not run under Windows 95, Windows Millennium, Windows 98, or Windows NT. Meta Imaging Series Software is not supported under any Windows Server version. 2. BackupBack up your existing Meta Imaging Series installation. If your Meta Imaging Series software was installed as suggested by its Setup routine, it may be found on drive C, in the MM folder and the folders within that folder. The backup for such an installation can be created by recording the c:\mm directory to a CD-R. Also back up any Meta Imaging Series files that are stored outside the MM folder on drive C. Because Meta Imaging Series software does not force the storage of all files within the MM folder, be sure to back up the files used by each person who uses the software. In particular, MetaMorph's High Content Screening (the commands Screen Acquisition, Review Screen Data or Screen Data Utilities) uses the ASSAY folder on drive C. 3. Configuration FilesUsing MetaMorph or MetaFluor, make sure that any protocol files, spatial calibrations, Integrated Morphometry Analysis settings, state files, or other configurations have been saved to a file using the "Save" button in each appropriate dialog box. For Multi-User configurations, each user must save their settings. 4. Acquisition SettingsUsing the Meta Imaging Series Administrator, open up the configuration dialog for each camera that you have installed and make careful note of the configuration settings. Should a power loss or other unforeseeable mishap cause the installation of your new version to be interrupted, it may be necessary for you to re-configure your cameras using this information. The configuration dialogs for the cameras may be found by choosing Configure Hardware, then choosing Configure Acquisition for each unique hardware setting, then proceeding down the list of Installed Drivers. As you reach each installed driver, highlight it in the list and press the Configure button. Note down the settings displayed by each tab of each camera driver's dialog. 5. Hardware Drivers/ Drop-ins Not Included
6. MetaMorph Drop-ins Not Included
7. UpdatesCheck the Meta Imaging Series Updates web site at www.meta.moleculardevices.com for any updates to your version and download them, to have them available for installation once the software has been installed. You can also view release notes (what's new) on this web site. 8. If You Need Further Assistance...As always, if you run into any problems during the installation process or you want some advice prior to performing the installation, please contact your local sales representative. If you do not know how to contact your local Meta Imaging Series representative, please refer to the Dealer Locator. You can contact Customer Support by telephone at +1-610-873-5610 ext. 3, by email at support.dtn@moldev.com, or by opening a Support Incident at our Support Online Web site at support.meta.moleculardevices.com. Begin the installation of Meta Imaging Series 6.1To install MetaMorph, insert your Meta Imaging Series CD into your CDROM drive. If the Installation Menu does not appear after a minute, select "Run" from the Start" menu and type d:\uicmenu.exe (where d is the letter of your CD-ROM drive).
If You Need Further Assistance...As always, if you run into any problems during the installation process or you want some advice prior to performing the installation, please contact your local sales representative. If you do not know how to contact your local Meta Imaging Series representative, please refer to the Dealer Locator on our Website under the Sales menu. You can contact Customer Support by telephone at +1-610-873-5610 ext. 3, by email at support.dtn@moldev.com, or by opening a Support Incident at our Support Online Web site at support.meta.moleculardevices.com. |
||